NITRILE MEDICAL GLOVES
TYPE
Powdered & Powder-Free, Non-sterile
MATERIAL
COLOUR
DESIGN & FEATURES
STORAGE
SHELF LIFE

Our Specifications
FUNCTIONAL BENEFITS
- Protection from unwanted and dangerous substances
- Beaded cuff ensures easy donning to prevent roll down
- Superior strength with better puncture resistance
- Finger or palm textured enhanced wet and dry grip
- Thinner gauge improves tactile sensitivity
- Custom design enhanced comfort and fit
- An alternative solution for individuals with allergies to natural rubber latex
QUALITY STANDARDS
- Conforms to ASTM D6319 and EN 455 Standards
- Manufactured under QSR (GMP), ISO 9001:2015 and ISO 13485:2016 Quality Management System
GLOVE SIZES
- Extra-Small, Small, Medium, Large, Extra-Large
- Size of gloves shall be marked in the check box on the shipping carton with black ink


Dimension | Mediblue | ASTM D6319 | EN 455 |
---|---|---|---|
Length (mm) | Min 230 Min 240 or 300 +/- 10 | Min 220 (XS, S) Min (M, L, XL) | Min 240 |
Palm Width (mm) XS S M L XL | 76 +/-3 84 +/-3 94 +/-3 105 +/-3 113 +/-3 | 70 +/- 10 80 +/- 10 95 +/- 10 110 +/- 10 120 +/- 10 | ≤ 80 80 +/- 10 95 +/- 10 110 +/- 10 ≥ 110 |
Thickness : Single Wall (mm) Finger Palm | Min 0.05 Min 0.05 | Min 0.05 Min 0.05 | N/A N/A |
Property | ASTM D6319 | EN 455 |
---|---|---|
Tensile Strength (MPa) Before Aging After Aging | Min 14 Min 14 | N/A N/A |
Elongation at Break (%) Before Aging After Aging | Min 500 Min 400 | N/A N/A |
Median Force at Break (N) Before Aging After Aging | N/A N/A | Min 6 Min 6 |
PRODUCT SAFETY CONFORMANCE
1.1) BIOCOMPATABILITY TESTED
Reference: ISO 10993-10 (Test for Skin Irritation and Skin Sensitization)
Purpose: Biological evaluation for medical devices for irritation and delayed type hypersensitivity
Reference: ISO 10993-10 (Test for Skin Irritation and Skin Sensitization)
Purpose: Biological evaluation for medical devices for irritation and delayed type hypersensitivity
Property | Test Results |
---|---|
Primary Skin Irritation | Passes
Not a primary skin irritant under condition of the study |
Skin Sensitization | Passes Not a contact sensitizer under condition of the study |
Reference: ASTM F1671 - Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood - Borne Pathogens Using Phi-X 174 Bacteriophage Penetration as a Test System
Purpose: To test the barrier protection of the gloves from the passages of the viruses
Viral Penetration | Test Results |
---|---|
Remarks: Applicable to selected products. Please liaise with our representative for further details. | Passes |
1.3) HEAVY METAL TESTED
Purpose: To ensure gloves are free from any chemical substances
Purpose: To ensure gloves are free from any chemical substances
Chemical Test (s) | |
---|---|
Not Detected | |
Lead (Pb) | Not Detected |
Mercury (Hg) | Not Detected |
Arsenic (As) | Not Detected |
Antimony (Sb) | Not Detected |
Tin (Sin) | Not Detected |
Purpose: To ensure gloves are free from any chemical substances
Not Detected | |
Remarks: Applicable to selected products. Please liaise with our representative for further details.
Contact MediBlue today for a quotation
The trusted market name for premium quality Nitrile Gloves